Halogen-free vs brominated flame retardants for polypropylene
In short
Brominated systems work in the gas phase and normally rely on antimony trioxide as a synergist. Halogen-free systems for polypropylene usually work by intumescent char formation, using phosphorus and nitrogen. Halogen-free avoids halogenated combustion products and antimony, but needs a tested formulation and attention to loading and processing.
Comparison
The brominated column is general background. The halogen-free column is taken from our own product pages and data sheets.
| Factor | Brominated with antimony trioxide | Halogen-free, phosphorus-nitrogen intumescent |
|---|---|---|
| Mechanism | Releases bromine radicals that interrupt combustion in the gas phase | Forms a swollen, insulating char on the polymer |
| Synergist | Antimony trioxide, typically | None needed with HOFNIL-38C |
| Loading in PP, by weight | Varies widely by product | HOFNIL-312A: 22-26% for UL 94 V-0. HOFNIL-37A: 28-30% for UL 94 V-0 at 1.6 mm |
| Halogen acid gas in a fire | Typically yes (hydrogen bromide) | None from an intumescent phosphorus-nitrogen additive |
| Smoke | Typically higher | Lower smoke and less toxic combustion products |
| Migration and bloom | Can occur with some brominated types | HOFNIL-38C does not migrate |
| Regulation | Some brominated substances are restricted under RoHS or REACH; check the specific substance | Check the specific substance too |
When to choose which
- Brominated: a legacy specification names it, or the lowest possible loading is decisive, and halogen content and smoke are not constraints.
- Halogen-free: the end customer asks for halogen-free or antimony-free, the part is used where smoke and halogenated gases matter (electrical housings, enclosed spaces, transport), or the specification limits halogen content.
- Either way: a UL 94 rating belongs to a test thickness, colour and filler. Test your own compound at the thickness you need.
Which of our products fits
These are our flame retardant routes for polypropylene.
- HOFNIL-312A, the UL 94 V-0 route. A nitrogen-phosphorus intumescent additive for PP homopolymer and copolymer, filled and unfilled. Loading 22-26% in PP for UL 94 V-0. Handle it to avoid moisture absorption.
- HOFNIL-38C, the UL 94 V-2 route. A low-dosage phosphorus-nitrogen additive. Compared with bromine-based flame retardants it needs a lower dosage, does not migrate and needs no antimony trioxide.
- HOFNIL-37A. An intumescent additive for polyolefins. Loading 28-30% in PP for UL 94 V-0 at 1.6 mm.
- HOFLENE flame retardant PP compound. Ready-to-mould, halogen-free pellets if you would rather buy the finished material. UL 94 V-0 and V-2 are stated on some grades.