ATH vs MDH vs APP for wire and cable compounds
In short
ATH (aluminium hydroxide) and MDH (magnesium hydroxide) are mineral hydroxides that work by absorbing heat and releasing water, and they need high loadings. ATH suits lower processing temperatures, MDH higher ones. APP (ammonium polyphosphate) is a phosphorus-based additive that works by forming a char and is used at lower loadings, typically inside an intumescent system in polyolefins.
Comparison
The ATH and MDH columns, and the typical ranges, are general background: check them against your supplier's data sheet. Figures for HOFNIL grades are from our own data sheets.
| Property | ATH (aluminium hydroxide) | MDH (magnesium hydroxide) | APP (ammonium polyphosphate) |
|---|---|---|---|
| How it works | Decomposes, absorbing heat and releasing water | Decomposes, absorbing heat and releasing water | Acid source in an intumescent system; forms an insulating char |
| Decomposition onset | Typically about 180-220 °C | Typically about 300-340 °C | HOFNIL-FR A2: 285 °C minimum; other grades vary |
| Typical loading in a polyolefin, by weight | Typically 50-65% | Typically 50-65% | Typically lower, as part of a phosphorus-nitrogen system |
| Water released, share of additive mass | About 35% | About 31% | None (not a hydrate) |
| Processing limit | The low onset is a problem in polymers processed hot | Higher; suits hotter extrusion | Depends on the grade and coating |
| Effect on mechanical properties | High loading reduces elongation and flexibility | The same, unless surface-treated | Lower loading, smaller effect |
| Halogen content | None | None | None |
| Smoke | Typically low | Typically low | Depends on the whole system |
| Solubility in water | Very low | Very low | HOFNIL-FR A2 and FR A2M: 0.50 g per 100 ml maximum at 25 °C |
When to choose which
- ATH: the compound is processed at low temperature (typically below about 200 °C), a high filler loading is acceptable and low smoke is the priority. Common in halogen-free cable compounds.
- MDH: the polymer has to be processed hotter than ATH tolerates.
- APP-based system: you need to cut the loading and protect flexibility or mechanical properties, in a polyolefin where intumescence suits. The system also needs a carbon source and a gas source, for example a melamine compound, and the result depends on the whole formulation.
- Blends: many compounds combine a hydroxide with a phosphorus system to reduce the total loading. This needs trials.
Cable standards set the real targets: for example IEC 60754 for halogen acid gas, EN 50575 for reaction to fire, and RoHS and REACH for substances. Specify against the standard your customer names, and test your own compound.
Which of our products fits
Our flame retardants are on the phosphorus side of this comparison.
- HOFNIL-FR A2 and FR A2M, ammonium polyphosphate. FR A2 is ammonium polyphosphate II. FR A2M is ammonium polyphosphate with a melamine coating, which improves thermal stability and water resistance. Data sheet values: FR A2 nitrogen 19.0-21.0%, phosphorus 20.0-22.0%, average particle size about 15 µm; FR A2M nitrogen 15.0-17.0%, phosphorus 31.0-32.0%, average particle size about 10-12 µm.
- Flame retardants for polyethylene. HOFNIL-312A and FR A2M, for polyethylene cable insulation and sheathing. They work by intumescence, which reduces dark smoke and carbon monoxide during combustion. Loading of HOFNIL-312A in PE: 25-28% for UL 94 V-0.
- HOFNIL-87R. A halogen-free phosphorus-nitrogen synergist. In wire and cable it helps reach the required LOI.